CW SPECIFICATIONS MANUAL (M) PROGRAMMABLE (P)
Phase Angle
Range -359 to +359 degrees. Positive phase
indicates time lag from reference
Accuracy within 100 microseconds of equivalent angle
Resolution 1 degree
MEASUREMENT
Voltage
Range 0 to 270 VRMS
Accuracy ±1% of range (>5 VAC out), ±0.1% of range <100 Hz, ±0.2% of range
measured at point of sense >100 Hz, measured at point of sense (>5 VAC out)
Resolution 0.1 VRMS
Current*
Range
CW 801 0 to 6.0 ARMS
CW 1251 0 to 9.4 ARMS
CW 2501 0 to 18.6 ARMS
Accuracy ±2% of range for linear loads with ±0.5% of range for linear loads
current >0.2A, > 0.4A for 2500 VA
Resolution 0.1 ARMS 0.01 ARMS
Peak Current*
Range
CW 801 0 to 25A
CW 1251 0 to 35A
CW 2501 0 to 70A
Accuracy ±2% of range
Resolution 0.1A
Frequency
Range 45 to 500 Hz (45 to 1000 Hz optional on programmable unit only)
Accuracy ±0.5% of reading ±0.02% of value
Resolution of display 0.1 Hz
Power*
Range
CW 801 0 to 800W
CW 1251 0 to 1250W
CW 2501 0 to 2500W
Accuracy ±2% of range for linear loads
Resolution 1W
Apparent Power*
Range
CW 801 0 to 800 VA
CW 1251 0 to 1250 VA
CW 2501 0 to 2500 VA
Accuracy ±2% of range for linear loads
Resolution 1 VA
*Note: In a parallel system (for programmable units only), the current/power displayed on the master unit is the sum of all units in the system.